翻訳と辞書
Words near each other
・ Secrets of the Masters
・ Secrets of the Moon
・ Secretary-General of the State Council
・ Secretary-General of the United Nations
・ Secretary-General to the President
・ Secretary-General's Internal Review Panel on United Nations Action in Sri Lanka
・ Secretarybird
・ Secretaría de Informaciones de Estado
・ Secretaría de Recreación y Deportes Francisco "Pancho" Coimbre
・ Secrete (helmet)
・ Secreted frizzled-related protein 1
・ Secretin
・ Secretin family
・ Secretin receptor
・ Secretin receptor family
Secretin-cholecystokinin test
・ Secretion
・ Secretion assay
・ Secretive dwarf squirrel
・ Secretiveness (phrenology)
・ Secretly
・ Secretly (Skunk Anansie song)
・ Secretly Canadian
・ Secretly Group
・ Secretly, Greatly
・ Secreto
・ Secreto a voces
・ Secreto de amor
・ Secreto de confesión
・ Secreto de confesión (1965 telenovela)


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Secretin-cholecystokinin test : ウィキペディア英語版
Secretin-cholecystokinin test
The secretin-cholecystokinin test (aka Secretin-CCK test, Secretin-Pancreozymin test〔Steer, et al. Medical Progress: Chronic Pancreatitis. N Engl J Med 1995; 332:1482-1490 June 1, 1995 DOI: 10.1056/NEJM199506013322206〕) is a combination of the secretin test and the cholecystokinin test and is used to assess the function of both the pancreas and gall bladder.
Cholecystokinin, a hormone secreted by the APUD cells located in the proximal mucosa of the small intestine is administered intravenously, this stimulates the pancreatic secretion of the digestive enzymes amylase, trypsin, and lipase. These are measured by a catheter placed in the duodenum. Cholecystokinin also stimulates the flow of bile and causes the gall bladder to contract and thus determine if the gall bladder is emptying properly. It also affects the esophageal sphincter and the sphincter of Oddi by reducing contraction as well as increasing motility (movement) of the stomach and intestine.
The CCK test may be administered in conjunction with an ultrasound test to visually monitor gall bladder contraction. While the test is usually administered in a supine position Dr. William Smedley of Wilkes Barre, Pennsylvania has detected previously missed gallbladder abnormalities by administering the test in an erect position.〔Burton P''et al.''The use of cholecystokinin to test gall bladder function in man. Gut. 1960 Sep;1:193-204. PMID 13689291〕〔Walkowiak J, Cichy WK, Herzig KH. Comparison of fecal elastase-1 determination with the secretin-cholecystokinin test in patients with cystic fibrosis.Scand J Gastroenterol. 1999 Feb;34(2):202-7. PMID 10192202〕〔Heij HA.et.''al.''Evaluation of the secretin-cholecystokinin test for chronic pancreatitis by discriminant analysis. Scand J Gastroenterol. 1986 Jan;21(1):35-40.
PMID 3952450〕
The concentration and output of bicarbonate with the secretin-CCK test is similar to what has been observed with the standard secretin test . The secretin-induced rapid flow of water results in lower and often unreliable enzyme concentrations. CCK also induces gallbladder contraction and the release of bile, which may further dilute enzyme concentrations. As a result, the quantification of total enzyme output (units/min) must be determined through continuous collection of duodenal fluid with or without the use of perfusion markers. Measurement of more than one enzyme (i.e. amylase, lipase, and tryptase) and bicarbonate may improve sensitivity since some patients may possess deficiencies of one parameter and not the others .
One study reviewed the relative diagnostic value of enzyme and bicarbonate concentrations compared with enzyme output in 363 secretin-CCK tests . The investigators also evaluated the requirement for perfusion markers to accurately quantify volume, and the validity of a shortened sampling time (first 20 minutes). Only 60 percent of volume was recovered with the duodenal aspiration tube, suggesting that marker perfusion to correct for distal loss of secretion is important to accurately quantify volume.
Using a trypsin output <50 U/kg/h as the reference standard, measurement of enzyme concentration alone misclassified approximately 10 percent of patients. Use of a shortened collection time misclassified approximately 4 percent of patients. The authors concluded that this was an unacceptably high rate of misclassification and that the standard prolonged collection of fluid using a perfusion marker must be performed to accurately measure exocrine function.